This instruction show you guide on how to solve ISUZU IDSS Scan Tool does not power up error.
Note:
Verify that the scan tool operates properly on another vehicle.
Related Contents:
ISUZU US-IDSS II 2024 2019 Diagnostic Software Free Download
2023 2019 Isuzu G-IDSS Export Diagnostic Software Free Download
ISUZU IDSS MX2-T Diagnostic Adapter
Nexiq USB Link 2
Steps:
1 IDSS interface power-up check
1) Check the LED power lamp of the IDSS interface. Does the LED power lamp illuminate?
Yes
=>Go to USB cable connection check.
No
=>Go to Smart cable and USB cable inspection.
2 USB cable connection check
1) Inspect for poor connections at the USB cable of the computer and IDSS interface.
2) Repair the connections as necessary.
Procedure completion
=>Go to Repair verification.
3 Smart cable and USB cable inspection
1) Inspect for poor connections at the smart cable of the DLC and IDSS interface. Is the connection status normal?
2) Inspect for poor connections at the USB cable of the computer and IDSS interface. Is the connection status normal?
3) Are all of the results normal?
Yes
=>Go to Fuse inspection.
No
Repair the connections as necessary.
=>Go to Repair verification.
4 Fuse inspection
1) Turn OFF the ignition switch.
2) Inspect the METER(+B) 10A fuse for a blowout. Is the result normal?
Yes
=>Go to DLC inspection.
No
Replace the fuse. If the fuse blows out again, repair the short to ground in the circuits relating to the METER(+B) 10A fuse.
=>Go to Repair verification.
5 DLC inspection
1) Inspect for poor connections at the DLC (C19). Is the connection status normal?
Refer to