Procedures:

1.Set the machine position for inspection and maintenance.

2.IMPORTANT
Set the key switch to the OFF position. Wait 5 minute or longer, and then set battery disconnect switch to the
OFF position.
Set the battery disconnect switch to the OFF position.

3.Open door (1).

4.Fold seat (2). Slide seat (2) to the front end.
5.Remove caps (3) (4 used).
6.Remove cover (4).

7.Remove screw (5), screws, washer (6), bolts (15), and washers (16). Remove the cover (14) assembly.
: 13 mm
8.Remove screws, washers (8) (2 used) and bolts, washer (10).
: 13 mm

9.Disconnect connector (17) and connectors (18) (2 used). Remove cover (9).

10.Remove screws, washers (7) (2 used), bolts (12) (2 used), and washers (13) (2 used). Remove the cover (11) assembly. At this time, duct (19) is also removed at the same time.
: 13 mm

11.Remove bolts, washers (21) (2 used). Remove Bracket (20).
: 13 mm

12.Disconnect connectors (25) (2 used).

13.Remove screws, washers (23) (4 used). Remove GSM (24) from bracket (22).

More repair cases for Hitachi excavator,please refer to:Hitachi Excavator Trouble Repair.

How useful was this post?

Click on a star to rate it!

Average rating / 5. Vote count:

This Post: HITACHI ZX-7 Excavator GSM Removal Guide From ChinaOBD2 Official Blog
Please keep this link if you copy the post!
Categories: Tech Support
Tags: key
" VCDS : ."