Here is a illustration for how to remove and install fuel transfer pump for Perkins 400A and 400D industrial engine.
Related Contents:
Newest Perkins EST 2020A & 2019A Full Support Free Download
Perkins SPI2 2018A EPC+Service Manual Free Download
Electrical Fuel Transfer Pump
Removal Procedure
NOTICE:Care must be taken to ensure that fluids are contained during performance of inspection, maintenance,testing, adjusting and repair of the product.Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids.
Dispose of all fluids according to local regulations and mandates.
Keep all parts clean from contaminants.
Contaminants may cause rapid wear and shortened component life.
Note: Put identification marks on all hoses, on all hose assemblies, on wires and on all tube assemblies for installation purposes. Plug all hose assemblies and tube assemblies. This helps to
prevent fluid loss and this helps to keep contaminants from entering the system.
1.Turn the fuel supply to the OFF position.
2.Turn the battery disconnect switch to the OFF position.
3.Disconnect harness assembly (1).
4.Loosen hose clamps (4) and (5). Disconnect hoses (6) and (7).
5.Remove bolts (2) and remove electric transfer pump (3).
Installation Procedure
1.Ensure that the electric transfer pump is clean and free from damage. If necessary, replace the electric transfer pump.
2.Position electric transfer pump (3) on the mounting and install bolts (2).
3.Tighten bolts (2) to a torque of 9 N