Removal
1.Turn the fuel supply to the OFF position.
2.Disconnect harness assembly (1) from electronic unit injector (2).
3.Remove valve bridges (3).
NOTICE
If the injector hold down bolt is loose during the removal procedure, inspect the injector bore for wear and debris. Replace the clamp and spacer.
4.Remove bolts (8) and washers (9). Remove harness assembly (1) and support bracket (7) as a unit.
5.Remove bolt (4) and spacer (5).
6.Place an identification mark on electronic unit injector (2) for installation purposes. Each electronic unit injector must be reinstalled in the original location in the cylinder head.
7.Use Tooling (A) to pry beneath the base and free electronic unit injector (2).
8.Remove electronic unit injector (2) and clamp (6) from the cylinder head.
9.Remove O-ring seals (11) and (12) from electronic unit injector (2).
Installation:
NOTICE
Keep all parts clean from contaminants.
Contaminants may cause rapid wear and shortened component life.
1.Use Tooling (D) to clean the carbon deposit from the inside of the electronic unit injector sleeve.
2.Use Tooling (B) to remove the fuel and oil from the cylinder. Evacuate as much fuel and oil as possible from the cylinder before installing the electronic unit injector. Several evacuations may
be necessary.
3.Ensure that seat area (X) on the electronic unit injector is clean and free carbon.
4.Install new O-ring seals (11) and (12) on the electronic unit injector. Lubricate the O-ring seals with clean engine oil.
5.Install a new O-ring seal (13) on the electronic unit injector.
Note: O-ring seal (13) should be installed dry.
NOTICE
If a replacement electronic unit injector is installed, the calibration code must be programmed into the electronic control module.
6.Install clamp (6) to electronic unit injector (2).
Install electronic unit injector (2) into the original location in the cylinder head.
7.Install spacer (5) and bolt (4). Tighten bolt (4) to a torque of 55 N
How useful was this post?
Click on a star to rate it!
Average rating / 5. Vote count:
Please keep this link if you copy the post!
Related Posts

Scania SDP3 V2.44.3 Scania Diagnos & Programmer 3 2.44.3 Free Download link
2020.08.19

BT TruckCom TE v2.8 Multilanguage Download
2019.07.19

Mercede Benz MB diagnostic tool reviews and comparison
2020.01.3

Bosch ADS625 Read & Clear DTCs for Volkswagen Passet GLS 2004
2019.07.19

All Benz diagnostic and programming: Benz Ecom VS SD C4
2019.03.8

Tata Vista & Manza Remote Programming by VVDI Key Tool
2019.03.21

WinOLS Tune ECU Map for Volvo 850 T5 Motronic 4.3 ECU
2019.02.24

How Configure Connection Between Scania VCI3 & PC by Wireless
2023.04.4

How to Use Cat ET and Cat 478-0235 Adapter 3 to Do ECM Clearing for Caterpillar
2024.01.24

How to Solve AllDATA Repair Software
2019.07.24