An overspeed error on the Perkins 1106D engine occurs when the engine speed exceeds the predefined overspeed trip point.
Preparations:
Perkins EST 2024A & 2023A & 2019A Software Free Download
Perkins SPI2 2018A EPC+Service Manual Free Download
Perkins Communication Adapter 3
Conditions that Trigger the Overspeed Error:
The overspeed error is logged when the engine speed surpasses the overspeed trip point. Refer to the relevant documentation for specific speed thresholds. Note: This is an event code and does not indicate a fault in the electronic system.
System Response:
Event Code Logging: When overspeed occurs, the system logs an event code.
The code can be viewed using the display module or an electronic service tool.
Performance Impact:
E362-1:
The warning light illuminates, and the diagnostic light flashes the event code.
Fuel injection is cut off until the engine speed drops 200 RPM below the overspeed trip point.
E362-3:
Both the warning and shutdown lights turn on, and the diagnostic light flashes the event code.
Important Notes:
This error signals excessive engine speed but does not indicate a failure in the Electronic Control Module (ECM) or the speed/time sensor.
No troubleshooting is required for this error.
Resolution:
Adjust the overspeed trip point using an electronic service tool if necessary.
Outcome:
The engine will stop once the issue is resolved, ensuring safe operation.
Related posts:
Perkins 1106D Generation CID 0003 FMI 05 Trouble Code Solution: Troubleshooting and Repair
How to Check Fuel Injection Timing for Perkins 800 Series Engine
Solution for Perkins 1106D Electric Power Generation with CID 0168 and FMI 02
Perkins EST software diagnostic Reviews
How useful was this post?
Click on a star to rate it!
Average rating / 5. Vote count:
Please keep this link if you copy the post!