New CAV DPA and DPS fuel injection pumps which will automatically eliminate air from the pump have been introduced on some engines. These pumps have a vent pipe (A1) fitted between the top of the pump and the atomiser leak-off pipe. Vent screws are not fitted to these pumps and connections or plugs need not be released to eliminate air from the pump.
Related Contents:
Newest Perkins EST 2022A & 2019A Full Support Free Download
Perkins SPI2 2018A EPC+Service Manual Free Download
To eliminate air from the fuel system
If the system or a component in the system has been drained:
1 Turn the start key to the