This instruction show you guide on how to use DMS-5 diagnostic software to calibrate swash plate angle for Doosan excavator.
Related Contents:
Doosan Data Monitoring System DMS-5 DMS-3 Free Download
Daios Doosan EPC Excavator Part Catalog 2017 Download & Installation
Procedures:
Swash Plate Angle Calibration
<Pump Swash plate angle sensor calibration concept>
1. In the case of VBO, the flow rate of the pump is controlled based on the swash plate angle sensor value, so the
sensor value must be measured at the maximum/minimum of the swash plate angle and calibration to the Software
reference value for accurate flow control.
2. That is, by measuring the swash plate angle sensor output(voltage) when the pump is at the maximum/minimum
position to calibrate the maximum/minimum swash plate angle value. 3.
3. For example, theoretically, the sensor output voltage at the maximum/minimum swash plates is at 4.5/0.5V, but if
the actual sensor value is 4.4/0.4V, it will be calibrated at 4.4V and the minimum at 0.4V.
<Caution>
1. The green light meaning of the displayed value is an indication that the tolerance for mounting the pump angle
sensor is within range, meaning no calibration is required. It is recommended that the measurements be calibration for
precise control.
2. That is, click