X

How to Solve JCB AGCO Power K4714 Intake Air Pressure Out of Range

This instruction show you guide on how to repair JCB AGCO power trouble code K4714 intake air pressure out range error.More repair case for JCB,please refer to:JCB Trouble Repair

Related Content:

WinEEM4s JCB Service Tool 2.7.2 2.6.1 Free Download

2020 JCB ServiceMaster 4 Free Download for Win XP,Win 7,Win 8,Win 10

 

The EEM monitoring system has detected that the intake 1 pressure sensor value is implausible.

 

Possible causes are:

The sensor wiring contact is loose.

The sensor wiring is defective.

The sensor is defective.

 

Reaction in EEM

The FC is stored and the warning lamp is activated. Engine power will be reduced (Degradation Level 3). The CAN message indicates active fault.

 

Solution

First save the error log and then erase it. Restart the ECU after erasing the error log. If the fault occurs again during the next driving cycle, check the following paths:

Check the intake 1 Boost and temperature sensor wiring, the connectors and the contact surfaces of the connector pins (possible oxidation).

Check the operation with another intake temperature and pressure sensor to see if the sensor is defective.

(Visited 50 times, 1 visits today)

How useful was this post?

Click on a star to rate it!

Average rating / 5. Vote count:

This Post: How to Solve JCB AGCO Power K4714 Intake Air Pressure Out of Range From ChinaOBD2 Official Blog
Please keep this link if you copy the post!
Categories: Tech Support