X

How to Setup MTU Diasys with MTU USB-to-CAN Adapter

Some customers always get communication error when they using MTU USB to CAN diagnostic adapter with MTU Diasys diagnostic software.Because they don’t know how to configure it.Here car-auto-repair.com show you guide how to do that.

 

Preparations:

MTU DiaSys 2.73 2.72 Engine Diagnostic Software Free Download

MTU Engine Diagnostic USB-to-CAN Adapter with Cables

 

Procedures:

Step 1:

If you driver has not been installed,please go to MTU USB to CAN Diagnostic Adapter Driver Free Download to download and install driver.

After driver installation,plug MTU US-to-CAN diagnostic adapter to PC and Engine

Go to “Device manager”,it show like picture

 

Step 2:

Right click “VCI4 USB-to-CAN V2 compact”,and select “Properties” and check general

Location show port #0001

 

Step 3:

Run MTU DiaSys diagnostic software,select correct engine ECU type

Then select “Option” to hardware/interface diagnostic port setting to select “COM 1” or ”COM2”

Click “OK”

 

Step 4:

Now click “New unit’s assembly description”,here you need input some information like order number/engine number

Click “OK”,and click “Create”

 

Step 5:

Select “Establish data link”

Click “COM 1” to select the order number/engine number you input previous

Tick the option “Establish online connection”

Then click “ok”

If everything setup well,the communicate between PC and MTU engine will build successfully.

If it prompt you with error information

“Controller could not be addressed”

“Examine serial data link to controller”

“Examine power supply of controller”

Please check the cable connect correctly?

Power supply?

How useful was this post?

Click on a star to rate it!

Average rating / 5. Vote count:

This Post: How to Setup MTU Diasys with MTU USB-to-CAN Adapter From ChinaOBD2 Official Blog
Please keep this link if you copy the post!
Categories: Tech Support