Here is the instruction show you guide on how to perform revering valve operation for HITACHI ZX-6 excavator.
What You Need?
Hitachi Dr.ZX diagnostic Tool
Hitachi AllinOne MPDr v3.32 v2.25 2021 Diagnostic Software Free Download
Connect Hitachi Dr.ZX cable to HITACHI ZX-6 excavator diagnostic port
Then Run HITACHI AllinOne software on desktop
Select “Functions”à”Engine”à”Active Test”
Then select “Operation Check of Revering Valve”
Please carry out only in the state of key switch ON
Revering Valve checking of operations cannot be carried out during engine operation
It cannot carry out,when DEF/AdBlue tank temperature or DEF/AdBlue supply module temperature is less than-5 deg C.
Please carry out after carring out warmth of the body and carring out DEF/AdBlue tank temperature and DEF/AdBlue supply module temperature more than -5 degC.
Procedures:
1 Please change into a key switch ON state (Engine Stopped)
2 Depress start button
One time 60 seconds turns on a valve (Opened),it turn off automatically in 60 seconds (Closed)
3 Please check whether the operation sound of Reverting Valve in a DEF/AdBlue supply module can be heard
4 After work,turn key OFF
Click [Start].
The forced operation is continued while “Executing” is displayed.
Click [Stop] if you want to stop the forced operation.
Turn the key switch OFF.
More repair case for Hitachi,please refer to Hitachi excavator trouble repair
How useful was this post?
Click on a star to rate it!
Average rating / 5. Vote count:
Please keep this link if you copy the post!