Here is the instruction show you guide on how to calibrate 1001 crossgate for Fendt 1000 S4 tractor.
Crossgate lever
A Raise
B Lower/press
C Floating position
Related Contents:
FENDT Fendias 2024.v2 with USB Dongle
AGCO 2×4 CANUSB
Procedures:
Important: Refer to Service Information 18/2012.
1 Apply the hand brake
2 Switch on ignition.
3 Press to confirm any existing errors displayed in the instrument cluster
4 Press to display the first main menu level
5 Press until symbol A flashes
6 Press to display the second main menu level
7 Press until symbol A flashes
8 Press to display the auxiliary spool valve menu level
9 Press until symbol A flashes
10 Press to be able to enter the calibration code
11 Press and enter code 1001
12 Confirm with
13 Release crossgate lever → it centers automatically
14 Confirm with
15 Push and hold the crossgate lever fully right (with the spring)
16 Confirm with
17 Push and hold the crossgate lever fully left (with the spring)
18 Confirm with
19 Push and hold the crossgate lever fully forwards (with the spring)
20 Confirm with
21 Push and hold the crossgate lever fully backwards (with the spring)
22 Confirm with
23 Push and hold the crossgate lever fully right (with the spring)
24 In this position, push and hold the crossgate lever fully forwards (with the spring)
25 Confirm with
26 Push and hold the crossgate lever fully right (with the spring)
27 In this position, push and hold the crossgate lever fully backwards (with the spring)
28 Confirm with
29 Push and hold the crossgate lever fully left (with the spring)
30 In this position, push and hold the crossgate lever fully backwards (with the spring)
31 Confirm with
32 Push and hold the crossgate lever fully left (with the spring)
33 In this position, push and hold the crossgate lever fully forwards (with the spring)
34 Confirm with
35 Push and hold the crossgate lever fully right (not with the spring)
36 Confirm with
37 Push and hold the crossgate lever fully left (not with the spring)
38 Confirm with
39 Push and hold the crossgate lever fully forwards (not with the spring)
40 Confirm with
41 Push and hold the crossgate lever fully backwards (not with the spring)
42 Confirm with
43 If calibration is error-free, OK appears and the calibration values are stored
Note:
The values are not applied until after a key reset.
Wait at least 60 seconds before switching the ignition ON.
44 If incorrect values are detected or the conditions were not met, ERROR appears
1001
Calibration code
FXX
Fault code
How useful was this post?
Click on a star to rate it!
Average rating / 5. Vote count:
Please keep this link if you copy the post!