Doosan Machine Bypass Cut-off EPPR Valve Check.
Related Contents:
Doosan Data Monitoring System DMS-5 DMS-3 Free Download
Doosan Diagnostic Tool
Bypass Cut-off EPPR Valve Check
*Calibration judgement
6.1. Measure the input & output current of the bypass cutoff valve in certain condition
Ex) DX350LC-7, Normal outputs of bypass cutoff valve (Please refer the shop manual to check the exact value on each model)
The bypass valve opens while the engine is initially starting.
1) The bypass EPPR valve is open during engine startup (when at below 450 rpm): 0 mA
2) The bypass EPPR valve closes on the completion of engine startup (when at over 500 rpm): 600 mA
The bypass valve opens while the engine is warming up.
1) The bypass EPPR valve is open during engine warm-up (at a coolant temperature of below 15