This is illustration show you guide on how to solve P0096 air mass flow temperature physical range high.
Preparation:
Doosan Data Monitoring System DMS-5 DMS-3 Free Download
Doosan Diagnostic Tool
2023 Doosan Diagnostic Tool DDT & G2 Scan Software Free Download
1) Overview
CODE | REASON | EFFECT |
P0096 SPN 172 FMI 0 |
Connection problem Harness problem Sensor problem |
SVS Torque Limit 0% or 10% |
2) Component Location
3) Condition for Running Diagnostic
During engine running
4) Condition for Setting the Fault Code
If the sensed air mass flow temperature is greater than the higher threshold 125 deg C for duration 50ms, then a physical range check high error is detected and reported into the fault path P0096 fault.
5) Condition for Clearing the Fault Code
If the sensed air mass flow temperature is smaller than the higher threshold 125 deg C for a duration 50 ms, then the physical range check high error is healed and the error (if present) is cleared from the fault path P0096 fault.
6) Check List
Step | Inspection | Standard Value |
YES | NO |
1 | P0096 is occurred on diagnostic tool? | Step 2 | ||
2 | Turn off the Key switch and ECU power (after Key Off, please wait for 30sec), battery off |
Step 3 | ||
3 | Check sensor connection Connection problem? |
Do necessary repair |
Step 4 | |
4 | Check ECU connection Connection problem? |
Do necessary repair |
Step 5 | |
5 | Check sensor resistance Resistance problem? |
Change Sensor |
Step 6 | |
6 | Check continuity and electrical insulation Electrical problem? |
Fix harness | Call Hot-line |