Error Overview
This guide will walk you through resolving Deutz EMR3 engine error code 19 / 676 / ArHtCD_NoLd.
Error Description: AIR HEATER – ECU does not detect switching on the air heater relay during the readback process.
DEUTZ Error Code: 19
Blink Code (short-long-short): 2 – 6 – 3
SPN: 676
Possible FMI:
12: Error mode not recognized
4: Voltage too low or short circuit to -Ubatt
Preparations:
Deutz Diagnostic Kit DECOM for Deutz Engine
2023 Deutz Serdia2010 v14.1.9.1 Diagnostic Software Free Download
Symptoms and System Reactions
Error Indicator: Error lamp remains lit.
System Reaction: Warning.
Error Lamp Behavior: Continuously lit.
Self-Healing: No.
Signal Priority: 3.
Possible Causes
Relay is energized, but feedback is missing on the sense line.
Defective or incorrect wiring.
Faulty pre-heating component.
Damaged connecting cable.
Troubleshooting and Solutions
Using Deutz SerDia2010, take the following steps to resolve the issue:
Check Wiring of Pre-Heating Component: Ensure all wiring connections are secure and correctly installed.
Inspect the Relay: Verify that the relay is present and functional; replace if defective.
Test the Pre-Heating Component: Confirm functionality; replace if necessary.
Examine the Connecting Cable: Inspect for any signs of damage, and repair or replace if needed.
For more repair case of Deutz engine,please refer to:Deutz Engine Repair
Related posts:
How to Use Deutz SerDia2010 Tachograph Functions
2023 Deutz Serdia2010 v14.1.9.1 Diagnostic Software Free Download
Deutz Diagnose Kit Software Have to Use Software from VMware Workstation
How useful was this post?
Click on a star to rate it!
Average rating / 5. Vote count:
Please keep this link if you copy the post!