Removing the reverser drive
Raise the feed rake conveyor and secure by engaging the cutterbar cylinder safety lock.
Loosen and remove the set collar from the bearing plate.

Loosen the M 10 x 20 hex. bolt so that the bearing plate may be removed.

Remove the hose end that goes off to the tank from the hydraulic cylinder and plug it with a plastic cap.

Loosen the M 8 x 180 hex. bolt.
Remove the spring clamp.

Remove the M 8 x 65, the M 12 x 25 and the M 12 x 45 hex. bolts with eccentric bolt from the hydraulic cylinder and remove the cylinder.
Remove the supporting arm with the hydraulic motor and the drive gear.

Unscrew the M 8 x 25 hex. bolt from the face end of the hydraulic motor.

Using a two-legged puller and a M 8 hex. bolt with centraliser, pull off the gear.

Loosen the M 12 x 35 hex. bolts and remove the hydraulic motor from the supporting arm.